特点: 本身固有的平衡功能; 风速连续可调; 交流技术,离子发生指示; 应用: 医药设备制造; 电子组装生产线; 微电子制造等行业; |
斯蒂克ST104A离子风机是一种大风量,宽范围的离子消除器。中和时间快,离子风覆盖面积大,特别适用于电子,塑胶等行业。风量可在45---190CFM范围内调节,离子平衡电压为0V+/-10V.
STATICST104Ais a device which produces maximum air volume in benchtop static eliminator series .It neutralizes charge over large targeted surface especially in plastiv sheet fabrication and vacuum forming.Air volume is ranging from 45—190CFM.Ion balance voltage is0V(+/-10v)
Specification(技术参数)
Operating Voltage(操作电压) | 110v/60hzor220V/50HZ |
Ccrrent Consumption(消耗电流) | 3.0Aor1.5A |
Operating Temperature(操作温度) | 0---50℃ |
Size(外型尺寸) | 450mm(L)*220mm(W)*190mm(H) |
Weight(重量) | 8.5kg |
Air Volume(风量) | 45---190CFM |
Ion Balance(离子平衡) | 0V±10v |
Air Coverage(气流覆盖面积) | 60cm*120cm |
Decay Tdst Results(测试结果)
Testing Conditions(测试条件) | ||||
TestingVoltage(测试电压):1Kvto100Voperating Voltane(操作电压):110/220Vtemperature(环境温度):22℃ | ||||
Distance(距离) | 300mm | 600mm | 900mm | 1200mm |
Left300mm(左300mm) | 1.2s | 2.4s | 3.8s | 6.5s |
Center(中心) | 1.0s | 2.1s | 3.5s | 6.4s |
Right300mm(右300mm) | 1.1s | 2.2s | 3.7s | 6.2s |
备注:
1.测试距离单位为毫米,中和时间单位为秒。
2.测试数据以用ME268A静电测试仪测试结果为准。
3.测试的数据会因测试时的环境空气温湿度而有所变化。
Remarks:
1.Distance measured in mm,decay time measured in seconds.
2.Test data available ME268A Charged plate Analyzer.
Test figures are subjecffo the variation in the atmospheric condifeons.
类型 | 台式离子风机 | 品牌 | STAITIC |
型号 | ST104A | 离子风量 | 130(cfm) |
消电时间 | 0。1(s) | 输入电压 | 220/110(V) |
安装距离 | 100-900(cm) |